The Amazon Super cylinder has a Stainless Steel inner Vessel with a 20 YEAR guarantee. It is highly insulated and finished in a White Steel Casing.

Quite simply, a very high quality laser welded stainless steel vessel, manufactured to the highest standards.  The Amazon MK2 allows quick installation of the expansion vessel by screwing directly into the top of the cylinder, or if preferred this can be installed into the cold supply as standard. The use of an expansion vessel instead of an internal bubble, overcomes the problems of regularly recharging the bubble to avoid dripping discharge pipes.

Water Inlet Control assembly with filter and back feed protection, Immersion Heaters, Tundish, and Expansion Vessel  are  supplied loose for site installation.

DIRECT ELECTRIC AMAZON MK2
Unit sizes and details are as follows:

Unit Code Capacity (litres) Unit Height (mm) Expansion
Vessel (litres)
ASC-MK2-90-ELC 90 755 12
ASC-MK2-125-ELC 125 980
ASC-MK2-150-ELC 150 1105
ASC-MK2-170-ELC 170 1255
ASC-MK2-200-ELC 200 1455
ASC-MK2-250-ELC 250 1755 19
ASC-MK2-300-ELC 300 2065

Inlet Pressure Reducing Valve set at:    3 bar
Temperature & Pressure Relief:  7 bar   90°C
Expansion Relief:  6 bar

Other options include:

  • Fitted Immersion Heaters, Controller & Wiring
  • Expansion Vessel within Casing (see MK1)

These are aimed at minimizing the efforts of the installer on site

Water Inlet Control assembly with filter and back feed protection, Immersion Heater, Combined Cylinder & Overheat Thermostat, Boiler Cut-Off Valve, Tundish, and Expansion Vessel  are  supplied loose for site installation.

INDIRECT ELECTRIC AMAZON MK2
Unit sizes and details are as follows:

Unit Code Capacity (litres) Unit Height (mm) Turns of Coil Expansion
Vessel (litres)
ASC-MK2-90-IND 90 755 8 12
ASC-MK2-125-IND 125 980 8
ASC-MK2-150-IND 150 1105 9
ASC-MK2-170-IND 170 1255 11
ASC-MK2-200-IND 200 1455 12
ASC-MK2-250-IND 250 1755 14 19
ASC-MK2-300-IND 300 2065 16

Inlet Pressure Reducing Valve set at:    3 bar
Temperature & Pressure Relief:  7 bar   90°C
Expansion Relief:  6 bar

Other options include:

  • Fitted Primary Controls and Wiring
  • Expansion Vessel within Casing (see MK1)

These are aimed at minimizing the efforts of the installer on site