Johnson & Starley Ltd.
Heat Bank Thermal Store Units

Installation, Commissioning, Servicing, & Users Instructions

Heat Bank Thermal Store System GX - Direct Rapid

Publication ZZ            
14/10/00
Copyright DPS
1788-6

Heat Bank Thermal Store System  
Everest combination unit  
Single Heat Exchanger (30 ltr/min)  
Directly heated from remote source  
35mm Foam Insulation  
GX-Plan primary controls  
Directly Pumped Heating Circuit  
Fitted programmer  
Fitted Primary Pump, 5m head  
All fitted controls are wired  
Thermostatic Blending Valve 22mm  
Backup Immersion Heater  


1   Integral Feed & Expansion Tank
2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
6   Manual Air Vent
8   Filling Vent
9   Feed to Ball Valve
10  Isolating Valve
11  Y-Pattern Strainer (supplied loose)
12  Overflow (supplied loose)
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler
20  Return to Boiler
23  Flow to Heating Circuit
24  Return from Heating Circuit
27  Boiler Pump UPS 15/50
28  Heating Circuit Pump UPS 15/60
33  Programmer Danfoss CP715
34  Room Thermostat Danfoss RMT230 (supplied loose)
38  Cylinder Immersion Thermostat Danfoss ITC
40  Tight Fitting Lid
41  Primary Blending Valve
42  Wiring Centre

 

Unit ID

HBPP-130-GXHBPP-150-GXHBPP-180-GXHBPP-210-GXHBPP-250-GX

Capacity

130150180210250

Base Diameter

450450450450450

Overall Diameter

520520520520520

Height

11901330151017201980

Contents:
1. Introduction
2. General Requirements
3. Mains Water Supply
4. Connections:
5. Wiring
6. Filling
7. Commissioning
8. Fault Finding
9. Servicing
10. Spares
11. User Instructions