Heat Bank Thermal Store System
HBPP System F
Xcel unit for connection to remote F+E
Twin heat exchangers (45 ltr/min)
Indirect
35mm Foam Insulation
High duty primary coil
S-Plan primary controls
Fitted programmer
Fitted Primary Pump, 6m head
All fitted controls are wired
Thermostatic Blending Valve 1''
28mm Primaries
Backup Immersion Heater
Primary Feed from Store
|
Unit Code |
XHBPP-300-F-HX21-S28 |
|
Capacity [litres] |
300 |
|
Base Diameter [mm] |
500 |
|
Overall Diameter [mm] |
570 |
|
Height [mm] |
1760 |
2 Plate Heat Exchanger 3 Heat Exchanger Pump 4 Flow Switch 5 Thermostatic Blending Valve, Aquamix 1" 6 Manual Air Vent 7 Automatic Air Vent 8 Vent 11 Y-Pattern Strainer (supplied loose) 13 Cold Feed / Expansion 14 Immersion Heater 3kW Incaloy with Stat 16 Cold Mains In, 22mm 17 Hot Mains Out, 22mm 18 Drain Cock 19 Flow From Boiler 28mm 21 Flow to Primary Coil 22 Return from Primary Coil 23 Flow to Heating 28mm 25 By-Pass Connection 15mm 29 Primary Coil Balancing Valve 26 Primary Pump UPS 15/60 31 Primary Feed / Expansion Connection 33 Programmer Danfoss CP715 34 Room Thermostat Danfoss RMT230 (supplied loose) 35a Two Port Zone Valve - Hot Water 22mm 35b Two Port Zone Valve - Heating 28mm 38 Cylinder Thermostat Danfoss ATC 42 Wiring Centre
|
Laing
Homes, Pinner |