Heat Bank Thermal Store System Xcel unit for connection to remote F+E Twin heat exchangers (45 ltr/min) Directly heated from remote source 40mm Foam Insulation GX-Plan primary controls Underfloor Primaries Danfoss VMV25 UF Control Valve All fitted controls are wired Thermostatic Blending Valve 1'' 28mm Primaries Additional 6m Finned Coil Flow Switch By-Pass Secondary Return Pump Sensor Pockets Cased
Unit Code |
HB-300-X24 |
Capacity [litres] |
300 |
Base Diameter [mm] |
500 |
Overall Diameter [mm] |
580 |
Height [mm] |
1600 |
2 Plate Heat Exchanger 3 Heat Exchanger Pump 4 Flow Switch 5 Thermostatic Blending Valve, Aquamix 1" 6 Manual Air Vent 8 Vent 11 Y-Pattern Strainer (supplied loose) 13 Cold Feed / Expansion
15 Backup 3kW Immersion Heater 16 Cold Mains In, 22mm 17 Hot Mains Out, 22mm 18 Drain Cock 19 Flow From Boiler 28mm 20 Return to Boiler 23 Flow to Heating 28mm 24 Return from Heating Circuit 26 Primary Pump - Grundfos Alpha 6m 38 Cylinder Immersion Thermostat 41 Primary Blending Valve 42 Wiring Centre 44 Flow to Lower Coil, 22mm 45 Return from Lower Coil, 22mm 48 Check Valve
64 Spare Bosses 73 Sensor Points at 0, 25, 50, 75, 100% of store 74 UP 15 40-P Bronze Secondary Circulator 75 Secondary Return 76 Danfoss VMV25 Valve with RAVK Sensor
|
|
The GXV Xcel a superb all-round performance system, originally designed as a compact, high output hot water and heating system for council properties. To obtain 100% useful input from the boiler, the store
is heated directly by the boiler - no coils. A feed and expansion tank must be
fitted above the highest point in the primary system. The main advantages of the system are...
No Motorised Valves for either hot water or heating - more reliable & easier
to service.
Very rapid recovery of store - hot water in under 3 minutes from cold.
Large volumes of hot water from a small store.
Maintains condensing boilers in condensing mode.
Ability to bring central heating up to temperature extremely quickly (store
recovered).
Store acts as an ideal air separator. | The Flow Switch is fitted with a 22mm By-Pass. This can be used to reduce the mains pressure drop
across the unit. The valve should be balanced so that the Heat Exchanger Pump [3] switches on at the minimum hot water flow rate. | The unit is fitted with two heat exchangers, and is capable of delivering 45 litres/minute @45°C (80°C storage). | A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4]. | It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor. | It is important that SENTINEL X100 Inhibitor is used to protect the Heat
Bank Thermal Store and primary system.
Use 1 litre per 100 litres of stored water. A suitable anti-freeze, such as X500, should also be added when there is a chance that the unit will be left filled and unheated in freezing conditions.
|
|
|
Please accept our quotation as follows the following:
Heat Bank Thermal Store System Xcel unit for connection to remote F+E As per specification 1564-1, 22-11-00 | Unit ID | Size | Net Price | HB-300-X24 | 300 litres, 500 x 1600mm | £ 1361.33 | Prices do not include VAT or Delivery. Ready for collection 3-4 weeks from receipt of order. Terms: 30 days Net. (account permitting)
|