DEDICATED PRESSURE SYSTEMS LTD.

Telephone 01372 803 675
Fax 01372 803 678
Email dps@heatweb.com
 
Internet http://www.heatweb.com

The Institute of Plumbing

R/O Shops, 9-19 Manor Green Road, Epsom, Surrey KT19 8RA

SPECIFICATION 1564-1
James Mansion

22/11/00
Copies / revised specifications
can be obtained via fax / email

Heat Bank Thermal Store System  
Xcel unit for connection to remote F+E  
Twin heat exchangers (45 ltr/min)  
Directly heated from remote source  
40mm Foam Insulation  
GX-Plan primary controls  
Underfloor Primaries  
Danfoss VMV25 UF Control Valve  
All fitted controls are wired  
Thermostatic Blending Valve 1''  
28mm Primaries  
Additional 6m Finned Coil  
Flow Switch By-Pass  
Secondary Return Pump  
Sensor Pockets  
Cased  

 

Unit Code

HB-300-X24

Capacity [litres]

300

Base Diameter [mm]

500

Overall Diameter [mm]

580

Height [mm]

1600

2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Aquamix 1"
6   Manual Air Vent
8   Vent
11  Y-Pattern Strainer (supplied loose)
13  Cold Feed / Expansion
15  Backup 3kW Immersion Heater
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler 28mm
20  Return to Boiler
23  Flow to Heating 28mm
24  Return from Heating Circuit
26  Primary Pump - Grundfos Alpha 6m
38  Cylinder Immersion Thermostat
41  Primary Blending Valve
42  Wiring Centre
44  Flow to Lower Coil, 22mm
45  Return from Lower Coil, 22mm
48  Check Valve
64  Spare Bosses
73  Sensor Points at 0, 25, 50, 75, 100% of store
74  UP 15 40-P Bronze Secondary Circulator
75  Secondary Return
76  Danfoss VMV25 Valve with RAVK Sensor

The GXV Xcel a superb all-round performance system, originally designed as a compact, high output hot water and heating system for council properties. To obtain 100% useful input from the boiler, the store is heated directly by the boiler - no coils. A feed and expansion tank must be fitted above the highest point in the primary system. The main advantages of the system are...
No Motorised Valves for either hot water or heating - more reliable & easier to service.
Very rapid recovery of store - hot water in under 3 minutes from cold.
Large volumes of hot water from a small store.
Maintains condensing boilers in condensing mode. 
Ability to bring central heating up to temperature extremely quickly (store recovered).
Store acts as an ideal air separator.
The Flow Switch is fitted with a 22mm By-Pass. This can be used to reduce the mains pressure drop across the unit. The valve should be balanced so that the Heat Exchanger Pump [3] switches on at the minimum hot water flow rate.
The unit is fitted with two heat exchangers, and is capable of delivering 45 litres/minute @45°C (80°C storage).
A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4].
It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor.
It is important that SENTINEL X100 Inhibitor is used to protect the Heat Bank Thermal Store and primary system.  Use 1 litre per 100 litres of stored water. A suitable anti-freeze, such as X500, should also be added when there is a chance that the unit will be left filled and unheated in freezing conditions.
 

Please accept our quotation as follows the following:

Heat Bank Thermal Store System
Xcel unit for connection to remote F+E
As per specification 1564-1, 22-11-00
Unit IDSizeNet Price
HB-300-X24300 litres, 500 x 1600mm£ 1361.33


Prices do not include VAT or Delivery.
Ready for collection 3-4 weeks from receipt of order.
Terms: 30 days Net. (account permitting)