DEDICATED PRESSURE SYSTEMS LTD.

Telephone 01372 803 675
Fax 01372 803 678
Email dps@heatweb.com
 
Internet http://www.heatweb.com

The Institute of Plumbing

R/O Shops, 9-19 Manor Green Road, Epsom, Surrey KT19 8RA

SPECIFICATION 1685-1

04/07/00
Copies / revised specifications
can be obtained via fax / email

Designed for Nick Pleasance
Heat Bank Thermal Store System  
Everest combination unit  
Single Heat Exchanger (30 ltr/min)  
Indirect  
35mm Foam Insulation  
High duty primary coil  
All fitted controls are wired  
Backup Immersion Heater  
Thermostatic Blending Valve 22mm  

Unit Code

1685.1.11685.1.21685.1.31685.1.41685.1.5

Capacity [litres]

130150180210250

Base Diameter [mm]

450450450450450

Overall Diameter [mm]

520520520520520

Height [mm]

11901330151017201980
UID: EHB450-IND-HX11-F35-W-IH-HDC-M22 

1   Integral Feed & Expansion Tank
2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
6   Manual Air Vent
7   Automatic Air Vent
9   Feed to Ball Valve
10  Isolating Valve
11  Y-Pattern Strainer (supplied loose)
12  Overflow (supplied loose)
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
21  Flow to Primary Coil
22  Return from Primary Coil
40  Tight Fitting Lid

 
Notes..
This system is a standard Indirect unit, with no frills. 
The unit is fitted with one plate heat exchanger, capable of delivering 30 litres of hot water per minute.
The unit uses a High Duty Coil to transfer heat from the primary system into the cylinder.
The Feed & Expansion Tank can double as the boiler F&E (top-up) Tank.