DEDICATED PRESSURE SYSTEMS LTD.

Telephone 01372 803 675
Fax 01372 803 678
Email dps@heatweb.com
 
Internet http://www.heatweb.com

The Institute of Plumbing

R/O Shops, 9-19 Manor Green Road, Epsom, Surrey KT19 8RA

SPECIFICATION 1709-1
Fairley Brown

27/07/00
Copies / revised quotations
can be obtained via fax / email

Heat Bank Thermal Store System  
HBPP System D  
Everest combination unit  
Single Heat Exchanger (30 ltr/min)  
Indirect  
35mm Foam Insulation  
High duty primary coil  
S-Plan primary controls  
Sealed primary system  
Fitted programmer  
All fitted controls are wired  
ACL Controls  
Backup Immersion Heater  
Fitted Primary Pump, Alpha 6m  
Thermostatic Blending Valve 22mm  

Unit Code

1709.1.11709.1.21709.1.31709.1.41709.1.51709.1.6

Capacity [litres]

130150180210250300

Base Diameter [mm]

450450450450450500

Overall Diameter [mm]

520520520520520570

Height [mm]

119013301510172019801900

1   Integral Feed & Expansion Tank
2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
6   Manual Air Vent
7   Automatic Air Vent
8   Air Vent
9   Feed to Ball Valve
10  Isolating Valve
11  Y-Pattern Strainer (supplied loose)
12  Overflow (supplied loose)
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler 28mm
19  Flow From Boiler
21  Flow to Primary Coil
22  Return from Primary Coil
23  Flow to Heating 28mm
23  Flow to Heating Circuit
25  By-Pass Connection 15mm
26  Primary Pump Grundfos Alpha 6m
29  Primary Coil Balancing Valve
30  Primary Expansion Vessel 8 litres
31  Primary Filling Point, with Check Valve
32  Pressure Relief Valve with Gauge 3 bar 1/2''
33  Programmer 
34  Room Thermostat  (supplied loose)
35a Two Port Zone Valve - Hot Water 22mm
35b Two Port Zone Valve - Heating 22mm
38  Cylinder Thermostat 
40  Tight Fitting Lid
42  Wiring Centre

 
Notes..
With Grundfos Alpha installing the circulation pump has become more convenient and easier than ever before. You simply plug and pump. Without even having to open the terminal box! Being automatic the pump itself applies the pressure and flow required by the system – regardless of the building or the time of year. And there’s noticeably less noise from pipes and radiators.

Grundfos Alpha has automatic control, which ensures that the pump’s pressure and flow is constantly adjusted to meet current needs - summer or winter, night or day.
An old-fashioned circulation pump pumps at the same power 24 hours a day – every day.

The automatic control ensures that the pump can “talk” with the heating system’s thermostats. When the heating is turned up the pump is hard at work. When the heating is turned down the pump works correspondingly less.
The improved balance between the pressure and flow produced by the pump and the throughput allowed by the thermostats also means reduced noise.

The unit is fitted with a Mixcall III Thermostatic Blending Valve, to control thehot water temperature, and prevent scalding.  The graph shows the pressure drop across the valve for various hot water flow rates.

The Valve is adjustable from 27°C to 67°C, and has a lockable head, as shown.

 

The unit is fitted with one heat exchanger, capable of delivering 30 litres/minute @45°C (80°C storage). The graphs shown the domestic hot water output that can be achieved for various storage temperatures.

  

A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4].
It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor.
It is important that SENTINEL X100 Inhibitor is used to protect the Heat Bank Thermal Store.  Use 1 litre per 100 litres of stored water. Label the unit as protected with the label provided.
A suitable anti-freeze, such as X500, should also be added when there is a chance that the unit will be left filled and unheated in freezing conditions. Please note, however, that adding anti-freeze into the store will not protect mains water pipework from freezing - these should be protected seperately (either by draining or by the application of trace heating).