Notes..
|
The unit is fitted with two heat exchangers, and is capable of delivering 45 litres/minute @45°C (80°C storage). | | The
unit has two coils, a standard (upper) coil for connection to a
boiler, and a finned (lower) coil for connection an Arga cooker.
Depending on the output of the Arga cooker and the length of
connecting pipework, a circulating pump may be required. It is
worth noting that it is possible to connect an Arga directly to a
Heat Bank Thermal Store, without the need for a coil - details upon request. | | A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4]. | | It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor. | It is important that SENTINEL X100 Inhibitor is used to protect the Heat Bank Thermal Store.
Use 1 litre per 100 litres of stored water. Label the unit as protected with the label provided. A suitable anti-freeze, such as X500, should also be added when there is a chance that the unit will be left filled and unheated in freezing conditions. Please note, however, that adding anti-freeze into the store will not protect mains water pipework from freezing - these should be protected
separately (either by draining or by the application of trace heating).
|
|
|
|