DEDICATED PRESSURE SYSTEMS LTD.

Telephone 01372 803 675
Fax 01372 803 678
Email dps@heatweb.com
 
Internet http://www.heatweb.com

The Institute of Plumbing

 9-19 Manor Green Road, Epsom, Surrey KT19 8RA

Specification 2001-2 Peter Lomax
Xcel Heat Bank Thermal Store, GX-VMV-Underfloor

02/08/01
Copies / revised specifications
can be obtained via fax / email

Heat Bank Thermal Store System  
Xcel Cylinder  
28 Plate Heat Exchanger (45+ ltr/min)  
Directly heated from remote source  
40mm Foam Insulation  
GX-Plan primary controls  
Danfoss VMV20 UF Control Valve  
Directly Pumped Heating Circuit  
Underfloor Primaries  
Fitted Primary Pump, 6m head  
All fitted controls are wired  
Thermostatic Blending Valve 22mm  
Secondary Return Pump  
Backup Immersion Heater  
Cased  
Primary Timeclock  
Relay for switching underfloor pump 3PCO 10A 

 

Unit Code

XC-210-2001-2

Capacity [litres]

210

Base Diameter [mm]

450

Overall Diameter [mm]

530

Height [mm]

1550

1   Remote Feed and Expansion Tank
2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
8   Vent
11  Y-Pattern Strainer (supplied loose)
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler,  22mm
20  Return to Boiler,  22mm
23  Flow to Heating Circuits, 22mm
24  Return from Heating Circuit,  22mm
26  Underfloor Pump - Grundfos UPS 15/50
27  Primary Pump UPS 15/60
28  Heating Circuit Pump UPS 15/50
38  Cylinder Thermostat (with Immersion Pocket)
39  White Coated Steel Casing
41  Primary Blending Valve
42  Wiring Centre
48  Check Valve
74  UP 15 40-P Bronze Secondary Circulator
75  Secondary Return, 15mm
76  Danfoss VMV20 Valve with RAVK Sensor
82  Secondary Return Thermostat