Heat Bank Thermal Store System Xcel Cylinder 28 Plate Heat Exchanger (45+ ltr/min) Directly heated from remote source 40mm Foam Insulation GX-Plan primary controls Danfoss VMV20 UF Control Valve Directly Pumped Heating Circuit Underfloor Primaries Fitted Primary Pump, 6m head All fitted controls are wired Thermostatic Blending Valve 22mm Secondary Return Pump Backup Immersion Heater Cased
Primary Timeclock
Relay for switching underfloor pump 3PCO 10A
Unit Code |
XC-210-2001-2 |
Capacity [litres] |
210 |
Base Diameter [mm] |
450 |
Overall Diameter [mm] |
530 |
Height [mm] |
1550 |
1 Remote Feed and Expansion Tank 2 Plate Heat Exchanger 3 Heat Exchanger Pump 4 Flow Switch 5 Thermostatic Blending Valve, Mixcall III 8 Vent 11 Y-Pattern Strainer (supplied loose) 13 Cold Feed / Expansion 14 Immersion Heater 3kW Incaloy with Stat 16 Cold Mains In, 22mm 17 Hot Mains Out, 22mm 18 Drain Cock 19 Flow From Boiler,
22mm 20 Return to Boiler, 22mm 23 Flow to Heating Circuits,
22mm 24 Return from Heating Circuit, 22mm 26 Underfloor Pump - Grundfos UPS
15/50 27 Primary Pump UPS 15/60
28 Heating Circuit Pump UPS 15/50 38 Cylinder Thermostat (with Immersion Pocket) 39 White Coated Steel Casing 41 Primary Blending Valve 42 Wiring Centre 48 Check Valve 74 UP 15 40-P Bronze Secondary Circulator 75 Secondary Return,
15mm 76 Danfoss VMV20 Valve with RAVK Sensor
82 Secondary Return Thermostat
|
|