Heat Bank Thermal Store System Stowaway advanced F+E Single Heat Exchanger (30 ltr/min) Immersion Heater Relays Electrically heated 40mm Foam Insulation All fitted controls are wired Manual Fill - No Overflow Full Low Water Level Cut-Out Central Overheat Protection Cased
1 Integral Expansion Vessel (Unpressurised) |
|
|||||||||||||||||||||||||
Both Immersion Heaters [14,15], the Pump [3], Flow Switch [4], are pre-wired to the Wiring Centre [42], and are isolated from their appropriate electrical supply until the unit is full, switched via the Level Switch [55] and relays. |
The unit is fitted with an Integral Overflow Chamber [8], which traps small volumes of water discharged as a result of overfilling. Water in the chamber can be drained off via the Overfill Drain Cock [66]. The unit MUST be watched during filling as excessive overfilling will result in over-spill onto the floor. |
The unit is fitted with one heat exchanger, capable of delivering 30 litres/minute @45°C (80°C
storage). The graphs shown the domestic hot water output that can be achieved for various storage temperatures.
|
A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4]. |
It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor. |
It is important that SENTINEL X100 Inhibitor is used to protect the Heat Bank Thermal Store. Use 1 litre per 100 litres of stored water. A suitable anti-freeze, such as X500, should also be added when there is a chance that the unit will be left filled and unheated in freezing conditions. |