Heat Bank Thermal Store System Pressurised Xcel GX Cylinder 28 Plate Heat Exchanger (45+ ltr/min) 40mm Foam Insulation Danfoss VMV20 GX Control Valve Underfloor Primaries 35mm Heating using UPS25-55 Fitted Primary Pumps All fitted controls are wired Backup Immersion Heater Cased
2 Plate Heat Exchanger
L18-28
|
|
||||||||||
IMPORTANT: A primary expansion vessel of at least 36 litres capacity, and with a 1 bar pre-charge pressure, must be connected to the return from the radiator circuit. There must be no valves, either manual or automatic, between the store and the vessel. |
To obtain 100% useful input from the boiler, the store
is heated directly by the boiler - no coils. The main advantages of the system are... No Motorised Valves for either hot water or heating - more reliable & easier to service. Very rapid recovery of store - hot water in under 3 minutes from cold. Large volumes of hot water from a small store. Maintains condensing boilers in condensing mode. Ability to bring central heating up to temperature extremely quickly (store recovered). Store acts as an ideal air separator. |
The unit is fitted a 28 plate heat exchanger, and is capable of delivering 45 litres/minute @45°C (80°C storage). |
A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4]. |
It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor. |
It is important that SENTINEL X100 Inhibitor is used to protect the Heat Bank Thermal Store. Use 1 litre per 100 litres of stored water. A suitable anti-freeze, such as X500, should also be added when there is a chance that the unit will be left filled and unheated in freezing conditions. |