This article relates to those boilers and stoves in the Red 365 range that have the Systen Configuration option (1-5), namely:
CONF.1 DEFAULT : Eco OFF Active Phase : Pump ON if T H2O> Ton pump Pump OFF if T H2O< Ton pump - hysteresis pump No Active Phases : Pump ON for t Off Pump ( 10 min) if T H2O> Ton pump . Then check temp and...if T H2O > Set H2O - T hysteresis pump .....Pump ON If during t Off Pump ( 10 min) T H2O < Ton pump- T hysteresis ...Pump OFF and reset the t Off Pump ( 10 min) Thermostat management : T Amb: OK when the T Set Amb is OK T Amb: NO when the T Set Amb is 0.5°Clower than SET Default Auto Eco Off Summer / Winter function not active in this conf. ______________________________ _________________________ _________________________ _______ CONF.2 Summer / Winter function active in this conf. Summer: Auto Eco always active ( not possible to deactivate it from control panel ) Thermostat is not considered . WINTER : Active Phase : Pump ON if T H2O> Ton pump Pump OFF if T H2O< Ton pump - hysteresis pump No Active Phases : Pump ON for t Off Pump ( 10 min) if T H2O> Ton pump . Then check temp and...if T H2O > Set H2O - T hysteresis pump .....Pump ON If during t Off Pump ( 10 min) T H2O < Ton pump- T hysteresis ...Pump OFF and reset the t Off Pump ( 10 min) SUMMER: T set H2o - automatically set to T set H20 for DHW Auto Eco always ON Active Phase : Pump ON if T H2O> Ton pump Pump OFF if T H2O< Ton pump - hysteresis pump No Active Phases : Pump ON for t Off Pump ( 10 min) if T H2O> Ton pump . Then check temp and...if T H2O > Set H2O ( DHW) - T hysteresis pump .....Pump ON If during t Off Pump ( 10 min) T H2O < Ton pump- T hysteresis ...Pump OFF and reset the t Off Pump ( 10 min) Thermostat management : SUMMER : The 3 way valve always towards the DHW circuit . Auto Eco ON ( not possible to deactivate it ) The ambiance thermostat is not considered. WINTER: Auto Eco : OFF ( but it is possible to activate it) IF Set H2o ( heating) power goes to 1 but the Auto Eco CountDown starts only IF Tamb is OK. With boiler in Auto Eco it restarts quickly ( delay 10 sec) when the thermostat demands power BOTH : Water Flow sensor ( Or Thermostat with the water cylinder) to connect in the motherboard in AUX IN position ________ _________________________ _________________________ _________________________ ____ CONF.3 Summer / Winter function active in this conf Summer: Auto Eco always active ( not possible to deactivate it from control panel ) Thermostat is not considered . WINTER : Active Phase : T Set Cylinder : NOT OK >>>> 3 way valve on DHW position >>> pump is ON only when T H2o > T cylinder +3 degrees pump is OFF when T H2o < T cylinder +1,5 degrees T Cylinder is OK when it is T Set Cylinder + 2,5°C T Cylinder is NOT OK when it is T Set Cylinder +0,5°C >>>>>> Tset H20 become the T set DHW IF T Cylinder is OK>>>> 3 way valve on Heating position >>>> pump is ON only when T H2o > Ton pump pump is OFF only when T H2o < Ton pump No Active Phases : Pump ON for t Off Pump ( 10 min) if T H2O> Ton pump . Then check temp and...if T H2O > Set H2O ( DHW) - T hysteresis pump .....Pump ON If during t Off Pump ( 10 min) T H2O < Ton pump- T hysteresis ...Pump OFF and reset the t Off Pump ( 10 min) Thermostat / Probes management : NTC probe on 3-4 of the back connector Water Flow sensor is not heard in this conf. SUMMER: pump is ON only when T H2o > T cylinder +3 degrees pump is OFF when T H2o < T cylinder +1,5 degrees Eco Mode is always ON and IF Tset Cylinder is OK >>>>> Boiler Shutdown for Eco Mode If Tset H20 is OK >>>> power goes to 1 _ _________________________ _________________________ _________________________ ___________ CONF.4 Installer should set the Ton Pump and the T set H20 at an higher value compared to the setting in the Buffer Thermostat. Thermostat : Always ON NTC probe: Not Heard Auto Eco : Always ON T set H2o : Automatically set at 80°C Water Flow sensor : Not heard 3 way valve always directed towards the heating position When the Buffer Thermostat is OK >>>> the Boiler Starts the Auto Eco procedure to shutdown (even if Tset H20 is not OK) Pump Management : Active Phase : Pump ON if T H2O> Ton pump Pump OFF if T H2O< Ton pump - hysteresis pump No Active Phases : Pump ON for t Off Pump ( 10 min) if T H2O> Ton pump . Then check temp and...if T H2O > Set H2O - T hysteresis pump .....Pump ON If during t Off Pump ( 10 min) T H2O < Ton pump- T hysteresis ...Pump OFF and reset the t Off Pump ( 10 min) ___________________________ _________________________ _________________________ __________ CONF.5 Thermostat : Always ON NTC probe: to connect in pos 3-4 Auto Eco : Always ON T Buffer is OK when Tset Buffer + 0,5 °C T Buffer is NOT OK when Tset Buffer - 0,5 °C T set H2O : Automatically set at T Set Buffer +10°C Water Flow sensor : Not heard 3 way valve always directed towards the heating position Active Phase : pump is ON only when T H2o > T Buffer +3 degrees pump is OFF when T H2o < T Buffer No Active Phases : pump is OFF when T H2o < T Buffer ( there is not the t Off Pump) pump is ON if T H2O became > T Buffer +3°C
« Go back
Powered by Help Desk Software HESK - brought to you by Help Desk Software SysAid