SPECIFICATION 1613-1

24/06/00
Copies / revised specifications
can be obtained via fax / email

Designed for Standard 3 Bedroom House

Heat Bank Thermal Store System  
Stowaway advanced F+E  
Single Heat Exchanger (30 ltr/min)  
Indirect  
40mm Foam Insulation  
High duty primary coil  
Smartfit Y-Plan primary controls  
All fitted controls are wired  
Backup Immersion Heater  
Magnetic Scale Inhibitor  
Overflow in 15mm Copper  
Primary Filling Loop  
Thermostatic Blending Valve 22mm  
Cased  



Unit Code

1613.1.1

Capacity [litres]

150

Base Diameter [mm]

450

Overall Diameter [mm]

530

Height [mm]

1200
 

2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
5   Thermostatic Blending Valve, Mixcall III
7   Automatic Air Vent
10  Isolating Valve
11  Y-Pattern Strainer (supplied loose)
12  Overflow
13  Connection to Expansion Vessel
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler
21  Flow to Primary Coil
22  Return from Primary Coil
23  Flow to Heating Circuit
29  Primary Coil Balancing Valve
31  Primary Filling Point, with Check Valve
33  Honeywell Smartfit Control Centre
34  Honeywell Smartfit Room Unit, 7 day
35  Three Port Mid Position Valve
38  Honeywell Smartfit Cylinder Thermostat
39  White Coated Steel Casing
54  Filling Loop
60  Magnetic Scale Inhibitor

 


Notes..
  Smartfit 
Honeywell,  has swept aside the traditional problems and hasslesassociated with controls wiring and significantly reduced installation time andcosts into the bargain.
At the centre of Smartfit is a new connection box whichprovides plug-in or simple 2-wire connection for all space heating and hot watercontrols, completely eliminating the need for complex wiring diagrams.  Allthe controls have been designed for low voltage, polarity free connection.  Servicing  is quicker, chances of error are reduced to the minimum, and can beachieved with total confidence.  The elegant Smartfit controller puts easy programming and diagnostics at yourfingertips.  A built-in commissioning sequence and simple manual overridesassure maximum user convenience.
The unique built-in diagnostics programme automatically indicates a fault inthe system and highlights where the fault lies, cutting out guesswork and hassleand saving valuable time.
Extensive information, including  can be obtained from the HoneywellWeb Site
http:// honeywell1.datareturn.com/UK/homes/smartfit.htm
Stowaway Heat Bank Thermal Stores require an external 15mm copper overflow connection to be made. Plastic pipe should not be used. The overflow should be run to a minimum distance of 150mm above the top of the Heat Bank Thermal Store, terminating within 5m above or below the Heat Bank Thermal Store.
The unit is fitted with one heat exchanger, capable of delivering 30 litres/minute @45°C (80°C storage). The graphs shown the domestic hot water output that can be achieved for various storage temperatures.

  
 

A Mains Water Isolating Lever Valve must be fitted within the cylinder cupboard, in clear view and easily accessible. A Strainer (supplied loose) must also be fitted, down stream of the isolating valve, to protect the flow switch [4].
It is advised that the mains water is tested for hardness. In areas of hard water, we advise the use of a scale inhibitor.
A chemical corrosion inhibitor, such as Sentinal X100, must be added to the stored water within the cylinder. Anti-freeze should also be added where there is a possibility of prolonged exposure to sub-zero temperatures.

Installation Instructions