GX Heat Bank Thermal Store SYSTEM SPECIFICATIONS
For Vented Primary Systems

Ideal for:

Fixed Output or Modulating Boilers
Solid Fuel or Wood Burning Boilers
Electric / Solar / Geo-Thermal / Heat Pumps / Aga & Rayburn Cookers
Multiple Heat Sources to be used for either Hot Water or Heating
Where space for hot water storage is limited
Very rapid recovery of hot water

GXV units are Integrated Thermal Stores, where the water in the store is the SAME water that flows to radiators, or through the boiler, or even the underfloor heating pipework.

GX units are only suitable for a vented boiler / heating systems with a Feed & Expansion Tank.
Hot Water is supplied at full mains water pressure on all units - No Cold Storage Tank.

Based on Patented DPS Technology.

Originally designed as a very fast recovery system, getting rid of the standard indirect heating coil used to transfer heat from the boiler to the store. This allows the full boiler output to be used to heat up the store.  

Whereas coils heat from the bottom up, allowing no control over the amount of water heated, the GX system heats the store from the top down making it possible to only heat up small quantities of water (and allows over-sizing for special occasions without having to heat the entire store in normal use).  

Also, as the top of the store heats first, hot water to taps is available very quickly, from a cold cylinder - be it only in small quantities for a few minutes.  The boiler output will backup current hot water demand, adding to the effective capacity of the store in any given period.  A 100 litre store can suffice a 3 bedroom house with bathroom and en-suite !

Return to boiler temperature control comes with the GX, and can help improve efficiency of condensing boilers, while also allowing return temperatures to be raised for some oil boilers. 

Operation of the GX Heat Bank Thermal Store

50 Systems

Sample Specifications:

  DHW Plate Size DHW Blender GX Valve (Boiler) Pumped Radiator Circuit Pumped UFH Circuit Solar Coil Solid Fuel Boiler Connections Twin Cylinder Thermostats Controls
Specification 5845-1

28

28mm

28mm

     
Specification 4388-1 28 22mm 22mm          
Specification 4522-2 14 22mm 22mm 22mm       RF Programmable Rom Stats x2
Specification 5375-2 28 28mm 28mm 22mm      
Specification 5395-1 28 28mm 28mm 28mm Store Timer with Overheat Controls
Specification 5477-1 28 22mm 22mm 22mm    
Specification 5602-1 14 22mm 28mm       Fitted TP9 Programmable Room Stat with DHW Timing